Part Number Hot Search : 
E004198 ATC500S LV160T P1100E WA22A A1D47 T85HFL NC7NZ04
Product Description
Full Text Search
 

To Download HSP4321607 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 (R)
HSP43216
Data Sheet April 18, 2007 FN3365.9
Halfband Filter
The HSP43216 Halfband Filter addresses a wide variety of applications by combining fS/4 (fS = sample frequency) quadrature up/down convert circuitry with a fixed coefficient halfband filter processor as shown in the block diagram. These elements may be configured to operate in one of the four following modes: decimate by 2 filtering of a real input signal; interpolate by 2 filtering of a real input signal; fS/4 quadrature down conversion of a real input signal followed by decimate-by-2 filtering to produce a complex analytic signal; interpolate-by-2 filtering of a complex analytic signal followed by fS/4 quadrature up conversion to produce a real valued output. The frequency response of the HSP43216's halfband filter has a shape factor, (passband+transition band)/passband, of 1.24:1 with 90dB of stopband attenuation. The passband has less than 0.0003dB of ripple from 0fS to 0.2fS with stopband attenuation of greater than 90dB from 0.3fS to Nyquist. At 0.25fS the filter provides 6dB of attenuation. The HSP43216 processes data streams with word widths up to 16-bits and data rates up to 52MSPS. The processing throughput of the part is easily doubled to rates of up to 104MSPS by using the part together with an external multiplexer or demultiplexer. Programmable rounding is provided to support output precisions from 8-bits to 16-bits.
Features
* Sample Rates to 52MSPS * Architected to Support Sample Rates to 104MSPS Using External Multiplexer * Four Modes of Operation: - Interpolate by 2 Filtering - Decimate by 2 Filtering - Quadrature to Real Signal Conversion - fS/4 Quadrature Down Conversion Followed by Decimate by 2 Filtering * 16-Bit Inputs and Outputs * 67-Tap Halfband FIR Filter with 20-Bit Coefficients * Two's Complement or Offset Binary Outputs * Programmable Rounding on Outputs * 1.24:1 Filter Shape Factor * >90dB Stopband Attenuation * <0.0003dB Passband Ripple * Saturation Logic on Output
Applications
* Digital Down Conversion * D/A and A/D pre/post Filtering * Tuning Bandwidth Expansion for HSP45116 and HSP45106
Ordering Information
PART NUMBER HSP43216JC-52 HSP43216VC-52 HSP43216VC-52Z (Note) PART MARKING HSP 43216JC-52 HSP 43216VC-52 HSP 43216VC-52Z TEMP. RANGE (C) 0 to +70 0 to +70 0 to +70 PACKAGE 84 Ld PLCC 100 Ld MQFP 100 Ld MQFP (Pb-free) PKG. DWG. # N84.1.15 Q100.14x20 Q100.14x20
NOTE: Intersil Pb-free plus anneal products employ special Pb-free material sets; molding compounds/die attach materials and 100% matte tin plate termination finish, which are RoHS compliant and compatible with both SnPb and Pb-free soldering operations. Intersil Pb-free products are MSL classified at Pb-free peak reflow temperatures that meet or exceed the Pb-free requirements of IPC/JEDEC J STD-020.
1
CAUTION: These devices are sensitive to electrostatic discharge; follow proper IC Handling Procedures. 1-888-INTERSIL or 1-888-468-3774 | Intersil (and design) is a registered trademark of Intersil Americas Inc. Copyright Intersil Americas Inc. 2000, 2007. All Rights Reserved All other trademarks mentioned are the property of their respective owners.
HSP43216 Block Diagram
AIN0-15 INPUT DATA FLOW BIN0-15 CONTROLLER fS/4 QUADRATURE DOWN CONVERT PROCESSOR 67-TAP HALFBAND FILTER PROCESSOR fS/4 QUADRATURE UP CONVERT PROCESSOR OUTPUT DATA FLOW CONTROLLER/ FORMATTER BOUT0-15 AOUT0-15
SYNC USB/LSB MODE0-1 INT/EXT RND0-2 FMT OEA OEB CLK
Pinouts
HSP43216JC (100 LD MQFP) TOP VIEW
CLK GND MODE1 MODE0 AIN15 AIN14 AIN13 AIN12 AIN11 AIN10 AIN9 AIN8 AIN7 AIN6 AIN5 AIN4 AIN3 AIN2 AIN1 AIN0 100 99 98 97 96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81 VCC NC NC NC NC SYNC USB/LSB INT/EXT BIN0 BIN1 BIN2 BIN3 BIN4 BIN5 BIN6 BIN7 BIN8 BIN9 BIN10 BIN11 BIN12 BIN13 BIN14 BIN15 RND0 RND1 NC NC NC NC 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 RND2 OEB GND VCC BOUT0 BOUT1 BOUT2 BOUT3 BOUT4 BOUT5 BOUT6 BOUT7 BOUT8 BOUT9 GND BOUT10 BOUT11 BOUT12 BOUT13 BOUT14 80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51 NC NC NC NC FMT OEA VCC GND AOUT15 AOUT14 AOUT13 AOUT12 AOUT11 AOUT10 AOUT9 AOUT8 AOUT7 AOUT6 AOUT5 GND AOUT4 AOUT3 AOUT2 AOUT1 AOUT0 NC NC NC NC BOUT15
2
FN3365.9 April 18, 2007
HSP43216 Pinouts (Continued)
HSP43216 (84 LD PLCC) TOP VIEW
VCC CLK GND MODE1 MODE0 AIN15 AIN14 AIN13 AIN12 AIN11 AIN10 AIN9 AIN8 AIN7 AIN6 AIN5 AIN4 AIN3 AIN2 AIN1 AIN0
11 10 9 8 7 6 5 4 3 2 1 84 83 82 81 80 79 78 77 76 75
SYNC USB/LSB INT/EXT BIN0 BIN1 BIN2 BIN3 BIN4 BIN5 BIN6 BIN7 BIN8 BIN9 BIN10 BIN11 BIN12 BIN13 BIN14 BIN15 RND0 RND1
12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53
74 73 72 71 70 69 68 67 66 65 64 63 62 61 60 59 58 57 56 55 54
FMT OEA VCC GND AOUT15 AOUT14 AOUT13 AOUT12 AOUT11 AOUT10 AOUT9 AOUT8 AOUT7 AOUT6 AOUT5 GND AOUT4 AOUT3 AOUT2 AOUT1 AOUT0
Pin Description
NAME VCC GND CLK AIN0-15 BIN0-15 MODE0-1 INT/EXT SYNC TYPE I I I I I I +5V Power. Ground. Clock Input. (CMOS LEVEL). fS is the frequency of CLK Input Data Bus A. AIN0 is the LSB. Input data format is 16-bit Two's Complement. Input Data Bus B. BIN0 is the LSB. Input data format is 16-bit Two's Complement. The Mode Select Inputs set one of four operational modes as highlighted in Table 1. The Internal\External multiplexer select inputs set whether the data multiplex/demultiplex function required in the various operational modes is performed internally (High State) or externally to the chip (Low State). This input is used to synchronize the input sample stream with the zero degree phase of the up or down convert Local Oscillators. In the straight decimate modes, this input can be use to synchronize the input sample stream with a particular phase of the halfband filter. (See the Operational Modes Section for additional information). The Upper and Lower Sideband select line is used to specify the direction of frequency translation imparted on the data stream in the Down Convert and Decimate Mode and in the Quadrature to Real Convert Mode. (See Operational Modes Section for additional information). The Round Select inputs set the number of output bits from eight (RND = 000) to sixteen (RND = 110). Least significant output bits are zeroed. See Table 4. Three-State Control Output Bus A, OUTA0-15. Active Low. Three-State Control Output Bus B, OUTB0-15. Active Low. The Format select input is used to convert the two's complement output to offset binary (unsigned). When asserted high, the AOUT15 and BOUT15-bits are inverted from the normal two's complement representation. Output Bus A. AOUT0 is the LSB. Output Bus B. BOUT0 is the LSB. DESCRIPTION
USB/LSB
I
RND0-2 OEA OEB FMT AOUT0-15 BOUT0-15
I I I I O O
3
RND2 OEB GND VCC BOUT0 BOUT1 BOUT2 BOUT3 BOUT4 BOUT5 BOUT6 BOUT7 BOUT8 BOUT9 GND BOUT10 BOUT11 BOUT12 BOUT13 BOUT14 BOUT15
FN3365.9 April 18, 2007
HSP43216
fS /4 QUADRATURE DOWN CONVERT PROCESSOR 67-TAP HALFBAND FILTER PROCESSOR fS /4 QUADRATURE UP CONVERT PROCESSOR
INPUT DATA FLOW CONTROLLER
OUTPUT DATA FLOW CONTROLLER R E G
AIN0-15 R E G R E G R E G
R E G
DELAY 2 - 35
EVEN TAP FILTER SYNC USB/LSB
PIPELINE
R E G
M U X
RFRR NMEE DTGG
AOUT0-15
MUX 1 1 MUX 1,-1,1,.. -1,1,-1,.
MUX ...,2,-2,2 ..,-2,2,-2 12 12 MUX
OEA
fS/4 L.O.
+
BIN0-15 RR EE GG M U X R E G
R E G
DELAY 19
ODD TAP FILTER
PIPELINE
R E G RFRR NMEE DTGG BOUT0-15
OEB CLK MODE0-1 SYNC INT/EXT RND0-2 FMT USB/LSB
Indicates elements which operate at CLK/2 when the INT/EXT control input is high.
FIGURE 1. HALFBAND BLOCK DIAGRAM
Functional Description
The operation of the HSP43216 centers around a fixed coefficient, 67-Tap, Halfband Filter Processor as shown in Figure 1. The Halfband Filter Processor operates stand alone to provide two fundamental modes of operation: interpolate or decimate by two filtering of a real signal. In two other modes, the Quadrature Up/Down Convert circuitry operates together with the Filter Processor block to provide fS/4 Down Conversion with decimate by 2 filtering or Quadrature to Real Conversion. In Down Convert and Decimate mode, a real input sample stream is spectrally shifted by fS/4. Each component of the resulting complex signal is then halfband filtered and decimated by 2 to produce real and imaginary output samples at half of the input data rate. In Quadrature to Real Conversion mode, the real and imaginary components of a quadrature input are interpolated by two and halfband filtered. The filtered result is then spectrally shifted by fS/4 and the real component of this operation is output at twice the input sample rate.The HSP43216 is configured for different operational modes by setting the state of the mode control pins, MODE1-0 as shown in Table 1.
00 01 10 11
TABLE 1. MODE SELECT TABLE MODE1-0 Decimate by Two Interpolate by Two Down Convert and Decimate Quadrature to Real Conversion MODE
Input Data Flow Controller
The Input Data Flow Controller routes data samples from the AIN0-15 and BIN0-15 inputs to the internal processing elements of the Halfband. The data routing paths are based on mode of operation and are more fully discussed in the Operational Modes section.
fS /4 Quadrature Down Convert Processor
The fS /4 Quadrature Down Convert Processor operates as a Quadrature LO which provides the negative fS /4 spectral shift required to center the upper sideband of a real input signal at DC. This operation is equivalent to multiplying the real sample stream, x(n), by the quadrature components of the complex exponential e-j(/2)n as given below: x ( n )e -j ( n 2 ) = x ( n ) cos ( n 2 ) + jx ( n ) sin ( - n 2 )
(EQ. 1)
4
FN3365.9 April 18, 2007
HSP43216
For added flexibility, a spectrally reversed version of the above process may be realized by configuring the Down Convert processor to impart a positive fS /4 spectral shift on the input signal. This has the effect of centering the lower sideband of the input signal at DC and is achieved by reversing the sign of the sine term in the quadrature mix as shown below: x ( n )e j ( n 2 ) = x ( n ) cos ( n 2 ) + jx ( n ) sin ( n 2 )
(EQ. 2)
The direction of the spectral shift imparted by the Down Convert Processor is set by the Upper Sideband/ Lower Sideband control input, USB/LSB. When this input is high, a -fS /4 spectral shift is used to center the input signal's upper sideband at DC. When asserted low, a spectral shift of fS /4 is used to center the lower sideband at DC. The SYNC control input may be used to synchronize the incoming data stream with the zero degree phase of the complex exponential as described in the Operational Modes section. The real and imaginary sample streams generated by the down convert operation are passed to the Halfband Filter block on the upper and lower processing legs respectively. The Down Convert Processor is only active in Down Convert and Decimate Mode, MODE1-0 = 10. In the other modes, the data on the upper and lower processing legs pass unaltered.
The polyphase implementation of the halfband filter provides the flexibility to realize a variety of filter configurations. In Decimate by Two Mode, the outputs of the each polyphase branch are summed to yield the filter output. In Interpolate by Two mode, the polyphase filters produce independent outputs which are multiplexed into a single sample stream at the interpolated data rate. In the Up Convert and Down Convert Modes, the polyphase branches filter the real and imaginary components of a complex sample stream with the equivalent of identical 67Tap Halfband Filters. For these modes, the real component is processed by the Even Tap filter and the imaginary component is processed by the Odd Tap filter. The Operational Modes Section provides further details regarding the data flow and operation of the Filter Processor for the various modes.
0 -20
MAGNITUDE (DB)
-40
-60
-80
67-Tap Halfband Filter Processor
The processing required to implement the 67-Tap Halfband filter is distributed across two polyphase branches comprised of even and odd tap filters as shown in Figure 1. The Even Tap Filter performs a filtering operation using the even indexed coefficients (even phase) of the halfband filter. The Odd Tap Filter uses the odd indexed coefficients (odd phase) of the halfband filter. NOTE: the odd tap filter's processing reduces to a delay and scale operation since the center tap is the only non-zero odd tap for a halfband filter. Together the polyphase filters perform the sum of-products required to implement the 67-tap halfband filter in an architecture capable of supporting a variety of operational modes. The frequency response of the halfband filter is given graphically in Figure 2 and in tabular form in Table 3. Table 2 shows the different modes and the related frequency with which the spectra in Figure 2 is normalized.
TABLE 2. NORMALIZED FREQUENCY vs MODE MODE Decimate by Two Interpolate by Two Down Convert and Decimate Quadrature to Real fS CLK CLK/2 CLK CLK/2
-100
-120 0 fS/8 fS/4 3fS/8 FS/2 NORMALIZED FREQUENCY
FIGURE 2. FREQUENCY RESPONSE OF 67-TAP HALFBAND FILTER
As a standard DSP term, group delay is defined as the time it takes to obtain valid filtered data given a certain input pattern. Both the Even Tap and Odd Tap filters have an identical group delay of 19 clocks relative to the operating mode of the halfband. The group delay has been specified in the data flow diagrams following this section. The delay clocks equal CLK when INT/EXT = 0 and CLK/2 when INT/EXT = 1.
NOTE: Pipeline delay specifies the time it takes for bits to toggle at the output given a certain input pattern. The Odd tap filter has a pipeline delay of 19 CLKs with respect to the operating mode because it consists of only the center tap of the 67-tap halfband. The Even tap filter has a pipeline delay of 2-35 CLKs with respect to the operating mode.
5
FN3365.9 April 18, 2007
TABLE 3. FREQUENCY RESPONSE OF THE 67-TAP HALFBAND FILTER NORMALIZED TO THE MODE SPECIFIC SAMPLE RATE FREQUENCY (NORMALIZED) 0.000000 0.003906 0.007812 0.011719 0.015625 0.019531 0.023438 0.027344 0.031250 0.035156 0.039062 0.042969 0.046875 0.050781 0.054688 0.058594 0.062500 0.066406 0.070312 0.074219 0.078125 0.082031 0.085938 0.089844 0.093750 0.097656 0.101562 0.105469 0.109375 0.113281 MAGNITUDE (dB) -0.000256 -0.000143 -0.000071 -0.000013 -0.000004 -0.000001 0.000032 -0.000000 -0.000026 0.000002 0.000036 0.000050 0.000021 0.000008 -0.000012 -0.000140 -0.000226 -0.000138 0.000010 0.000036 0.000179 0.000190 0.000064 0.000011 -0.000064 -0.000018 -0.000000 0.000020 0.000053 0.000012 FREQUENCY (NORMALIZED) 0.125000 0.128906 0.132812 0.136719 0.140625 0.144531 0.148438 0.152344 0.156250 0.160156 0.164062 0.167969 0.171875 0.175781 0.179688 0.183594 0.187500 0.191406 0.195312 0.199219 0.203125 0.207031 0.210938 0.214844 0.218750 0.222656 0.226562 0.230469 0.234375 0.238281 MAGNITUDE (dB) -0.000278 -0.000098 0.000001 0.000077 0.000166 0.000106 0.000015 -0.000022 -0.000048 -0.000074 -0.000022 0.000005 0.000009 0.000041 0.000095 0.000090 -0.000012 -0.000037 -0.000145 -0.000208 -0.000927 -0.005089 -0.018871 -0.053894 -0.128250 -0.266964 -0.501238 -0.866791 -1.401949 -2.145948 FREQUENCY (NORMALIZED) 0.250000 0.253906 0.257812 0.261719 0.265625 0.269531 0.273438 0.277344 0.281250 0.285156 0.289062 0.292969 0.296875 0.300781 0.304688 0.308594 0.312500 0.316406 0.320312 0.324219 0.328125 0.332031 0.335938 0.339844 0.343750 0.347656 0.351562 0.355469 0.359375 0.363281 MAGNITUDE (dB) -6.020594 -7.989334 -10.364986 -13.194719 -16.533196 -20.447622 -25.024382 -30.379687 -36.679477 -44.169450 -53.259353 -64.619008 -79.291213 -90.247748 -91.540418 -96.987389 -97.990997 -94.450644 -94.268681 -97.250387 -103.660592 -105.940671 -98.212931 -94.313447 -95.354251 -98.447393 -103.249457 -93.387604 -91.390894 -94.404415 FREQUENCY (NORMALIZED) 0.375000 0.378906 0.382812 0.386719 0.390625 0.394531 0.398438 0.402344 0.406250 0.410156 0.414062 0.417969 0.421875 0.425781 0.429688 0.433594 0.437500 0.441406 0.445312 0.449219 0.453125 0.457031 0.460938 0.464844 0.468750 0.472656 0.476562 0.480469 0.484375 0.488281 MAGNITUDE (dB) -90.469534 -91.528735 -98.960202 -105.235066 -97.073218 -101.790858 -103.660592 -96.903272 -97.160860 -106.804655 -96.213761 -91.368358 -91.202963
6
FN3365.9 April 18, 2007
HSP43216
-96.903271 -103.058722 -92.156508 -90.247741 -91.623161 -98.760392 -103.883238 -96.861830 -96.987388 -100.046559 -106.804655 -104.119091 -105.235066 -104.637666 -105.940673 -107.323099 -102.375213
0.117188 0.121094
-0.000022 -0.000149
0.242188 0.246094
-3.137997 -4.416657
0.367188 0.371094
-103.883234 -93.245384
0.492188 0.496094
-94.009640 -91.312516
HSP43216 fS /4 Quadrature Up Convert Processor
The fS/4 Quadrature Up Convert Processor provides the fS/4 spectral shift used to construct a real signal from a complex sample stream. The operation performed is equivalent to multiplying a quadrature data stream, i(n)+jq(n), by samples of a complex exponential, e-j(/2)n, and outputting the real part of that mathematical operation as given below: Real { (i (n) + jq(n) ) e j (n/2) } = Real {[i (n) cos (n/2) - q(n) sin (n/2)] + j [i (n) sin (n/2) + q(n) cos (n/2)]} = i (n) cos (n/2) - q(n) sin (n/2) = i (n) cos (n/2) + q(n) sin (-n/2)
(EQ. 3)
the Up Convert LO with a particular input sample as described in the Operational Modes Section. The Up Convert Processor also scales the data streams output from the Filter Processor as required by the operational mode. In the modes which employ interpolation, the Up Convert Processor scales the Filter Processor's output by two to compensate for the attenuation of one half caused by the interpolation process. In down convert and decimate mode, the filter processor output is also scaled by two to compensate for the attenuation introduced by the down covert process. The scaling operations performed are summarized in Table 4.
TABLE 4. SCALE FACTORS APPLIED BY UP CONVERT PROCESSOR vs MODE MODE Decimate by Two (MODE1-0 = 00) Interpolate by Two (MODE1-0 = 01) Down Convert and Decimate (MODE1-0 = 10) Quadrature to Real (MODE1-0 = 11) SCALE FACTOR 1.0 2.0 2.0 2.0
In the above operation, a positive fS/4 spectral shift is imparted on the quadrature input which causes the upper sideband of the resulting real output to be defined by the spectral content of the input signal as shown in Figure 3. For added flexibility, the Up Convert processor may be configured to impart a negative fS/4 shift on the quadrature input which generates a real output whose lower sideband is defined the spectrum of the quadrature input as shown in Figure 4. The state of the USB/LSB control input determines the direction of the spectral shift. If this input is set "High", a positive fS/4 shift is introduced by the Up Convert Processor. If USB/LSB is asserted "Low", a negative fS/4 spectral shift is introduced.
Output Data Flow Controller
The Output Flow Controller routes data to the AOUT0-15 and BOUT0-15 output depending on mode of operation. In decimate by two mode (MODE1-0 = 00), output from the filter processor's polyphase branches are summed and output through AOUT0-15. In Down Convert and Decimate mode (MODE1-0 = 10), real and imaginary data streams produced by the down convert process pass are output directly to AOUT0-15 and BOUT0-15 respectively. In the two modes using interpolation, MODE1-0 = 01 or 11, with internal multiplexing enabled, INT/EXT set high, data sam ples output from the polyphase branches are internally multiplexed into a single stream and output via AOUT0-15. If a mode using interpolation is specified together with external multiplexing, INT/EXT set low, the data stream multiplexing is performed off chip and the data on the upper and lower processing legs is output through AOUT0-15 and BOUT0-15. The Output Data Flow Controller also sets the binary format and precision of the two 16-bit outputs. The data format is specified as either two's complement (FMT input low) or offset binary (FMT input high). The precision of the output data is set from 8-bits to 16-bits via the round control inputs, RND2-0. The RND2-0 inputs round the output data to a precision ranging from 8-bits to 16-bits as specified in Table 5. Saturation logic is incorporated in the output flow controller to insure that numerical growth associated with a worst case signal input or rounding condition saturates to a 16-bit value.
-fS/2
-fS/4
0
fS/4
fS/2
-fS/2
-fS/4
0
fS/4
fS/2
FIGURE 3. fS/4 POSITIVE SHIFT: UP CONVERSION
-fS/2
-fS/4
0
fS/4
fS/2
-fS/2
-fS/4
0
fS/4
fS/2
FIGURE 4. fS/4 NEGATIVE SHIFT: DOWN CONVERSION
The Up Convert Processor implements the up convert operation by multiplying the in-phase and quadrature samples on the upper and lower processing legs by the nonzero sine and cosine terms in the above expression. The resulting data is then multiplexed together in the Output Flow Controller to yield the real output sample stream. The SYNC control input may be used to align the zero degree phase of
7
FN3365.9 April 18, 2007
HSP43216
TABLE 5. OUTPUT ROUNDING CONTROL RND 2-0 000 ROUND FUNCTION Round output to 8-bits, AOUT15-8 and BOUT15-8, zero lower bits. Round output to 9-bits, AOUT15-7 and BOUT15-7, zero lower bits. Round output to 10-bits, AOUT15-6 and BOUT15-6, zero lower bits. Round output to 11-bits, AOUT15-5 and BOUT15-5, zero lower bits. Round output to 12-bits, AOUT15-4 and BOUT15-4, zero lower bits. Round output to 14-bits, AOUT15-2 and BOUT15-2, zero lower bits. Round output to 16-bits, AOUT15-0 and BOUT15-0. Zero all outputs.
001
010
In the polyphase implementation, the input data is broken into even and odd sample streams which are processed by a set of polyphase filters running at one half of the input data rate. These filters are designated as even or odd tap filters depending upon whether the coefficients were derived from the even or odd indexed coefficients of the original transversal filter. This architecture only produces the outputs which are not discarded by the decimation process. NOTE: Since the only non-zero tap for a halfband filter is the center tap, the Odd Tap Filter reduces to a delay and multiply operation. The operation of the HSP43216 in Decimate by Two mode is analogous to the polyphase implementation in Figure 6. In this mode, the internal data paths are routed as shown in Figure 7A and Figure 7B. The different data flows depend on whether internal or external multiplexing has been selected using the INT/EXT control input. In either case, an input data stream is decomposed into even and odd sample streams which are then routed to the even and odd tap polyphase filters. The output of each polyphase filter is summed and output via AOUT0-15.
EVEN TAP FILTER ...,X4,X2,X0 C0 C2 C4 C6 ODD TAP FILTER ...,X5,X3,X1 R E G
011
100
101
110 111
Operational Modes
Decimate By 2 Filter Mode (Mode1-0 = 00)
The concept of operation for Decimate by Two Filter mode is most easily understood by comparing the 7 tap transversal filter implementation to the equivalent polyphase implementation. The transversal implementation is shown in Figure 5.
..,Y2,Y1,Y0
+
X3,X2,X1,X0 C0 C1 C2 C3 C4 C5 C6
...,Y1,Y0 2
..,Y4,Y2,Y0
C1 C3 C5
Y(0) = X0(C0)+X1(C1)+X2(C2)+X3(C3)+X4(C4)+X5(C5)+X6(C6) Y(1) = X2(C0)+X3(C1)+X4(C2)+X5(C3)+X6(C4)+X7(C5)+X8(C6)
Y(0) = X0(C0)+X1(C1)+X2(C2)+X3(C3)+X4(C4)+X5(C5)+X6(C6)
Y(1) = X1(C0)+X2(C1)+X3(C2)+X4(C3)+X5(C4)+X6(C5)+X7(C6)
Y(2) = X2(C0)+X3(C1)+X4(C2)+X5(C3)+X6(C4)+X7(C5)+X8(C6)
Y(3) = X3(C0)+X4(C1)+X5(C2)+X6(C3)+X7(C4)+X8(C5)+X9(C6)
FIGURE 6. POLYPHASE IMPLEMENTATION OF DECIMATE BY 2 HALFBAND FILTER
Indicates samples discarded by decimation process
FIGURE 5. TRANSVERSAL IMPLEMENTATION OF DECIMATE BY 2 HALFBAND FILTER
By inspecting the sum-of-products for the decimated output in Figure 5, it is seen that even indexed input samples are always multiplied by the even filter coefficients and the odd samples are always multiplied by the odd coefficients. This computational partitioning is realized in the polyphase implementation shown in Figure 6.
8
FN3365.9 April 18, 2007
HSP43216
PIPELINE DELAY 2-35 GROUP DELAY 19
EVEN TAP FILTER 1
AIN0-15 R E G R E G R E G
R E G
R E G AOUT0-15
1 1
R E G
R E G
PIPELINE DELAY 19 GROUP DELAY 19
ODD TAP FILTER
+
1
R E G
RFRR NMEE DTGG
Clocked at CLK/2
OEA
FIGURE 7A. DATA FLOW DIAGRAM FOR DECIMATE BY 2 FILTER MODE (INT/EXT = 1)
PIPELINE DELAY 2-35 GROUP DELAY 19 AIN0-15 R E G R E G R E G 1 1 BIN0-15 R E G R E G R E G R E G PIPELINE DELAY 19 GROUP DELAY 19 ODD TAP FILTER 1 R E G R E G EVEN TAP FILTER 1 R E G AOUT0-15
+
RFRR NMEE DTGG
OEA
FIGURE 7B. DATA FLOW DIAGRAM FOR DECIMATE BY 2 FILTER MODE (INT/EXT = 0)
If internal multiplexing is selected (INT/EXT = 1), the input data stream is decomposed into even and odd samples internally by the processing elements operating at one half of the input CLK (see elements marked by " " in Figure 7A). In this mode, the Data Flow Controller routes data samples input through AIN015 to upper and lower processing legs with a one sample relative delay. Since a new data sample is clocked into either of the processing legs at CLK/2, each leg processes a data stream comprised of every other input sample, and the one sample relative delay of each leg's input forces the even samples to be clocked into one leg while the odd samples are clocked into the other. The user may choose which sample gets routed to the upper (even) processing leg by asserting SYNC. Specifically, a sample input on the CLK following the assertion of SYNC will be routed to the upper processing leg as shown in Figure 8. With internal multiplexing, the minimum pipeline delay on the upper processing leg is 14 CLK's and the pipeline delay on the bottom leg is 47 CLK's. The filtered and decimated data stream is held on AOUT0-15 for 2 CLK's. If external multiplexing is selected (INT/EXT = 0), a demultiplex function is required off chip to break the input data into even and odd sample streams for input through AIN0-15 and BIN0-15. In this mode, the Data Flow Controller routes the even and odd sample streams directly to the following processing elements which are all running at the input CLK rate. This allows the device to perform decimate by two filtering on signals sampled at up to twice the maximum CLK rate of the device (104 MSPS). With external multiplexing, the minimum pipeline delay through the upper processing leg is 9 CLK's and the pipeline delay through the lower processing leg is 26 CLK's as shown in Figure 7B. In 9
this mode, SYNC has no effect on part operation. NOTE: For proper operation, the samples demultiplexed to the AIN0-15 input must precede those input to the BIN0-15 input in sample order. For example, given a data sequence x0, x1, x2 and x3, the demultiplex function would route x0 and x2 to AIN0-15 and x1 and x3 to BIN0-15.
0 CLK SYNC 1 2
AIN0-15
EVEN
ODD
EVEN
INPUTS DESIGNATED AS EVEN ARE PROCESSED ON THE UPPER LEG, INPUTS DESIGNATED AS ODD ARE PROCESSED ON THE LOWER LEG.
FIGURE 8. DATA SYNCHRONIZATION WITH PROCESSING LEGS (INT/EXT = 1)
Interpolate By 2 Filter Mode (Mode1-0 = 01)
As with the Decimate by Two mode the concept of operation for the Interpolate by Two Filter mode is more easily understood by comparing a 7 tap transversal filter implementation to the equivalent polyphase implementation. The transversal implementation is shown in Figure 9. By inspecting filter outputs in Figure 9, it is seen that the even indexed outputs are the result of the sum-of-products for the odd coefficients, and the odd indexed outputs are the result of the sum-of-products for the even coefficients. This computational partitioning is evident in the polyphase implementation shown in Figure 10.
FN3365.9 April 18, 2007
HSP43216
7 TAP HALFBAND FILTER ..,X2,X1,X0 2 C0 C1 C2 C3 C4 C5 C6 Y(0) = 0(C0)+X0(C1)+0(C2)+X1(C3)+0(C4)+X2(C5)+0(C6) Y(1) = X0(C0)+0(C1)+X1(C2)+0(C3)+X2(C4)+0(C5)+X3(C6) Y(2) = 0(C0)+X1(C1)+0(C2)+X2(C3)+0(C4)+X3(C5)+0(C6) Y(3) = X1(C0)+0(C1)+X2(C2)+0(C3)+X3(C4)+0(C5)+X4(C6) ..X1,0,X0,0 ...,Y1,Y0
In the polyphase implementation, the input data stream feeds even and odd tap filters running at the input sample rate. The interpolated sample stream is derived by multiplexing the output of each polyphase branch into a single data stream at twice the input sample rate. As in the Decimate by Two example, the even or odd tap filters are comprised of the even or odd indexed coefficients from the original transversal filter. The operation of the HSP43216 in Interpolate by Two mode is analogous to the polyphase example above. In this mode the internal data flow is routed as shown in Figure 11A and Figure 11B. The different data flows depend on the selection of internal or external multiplexing via INT/EXT. In this mode, data input through AIN0-15 is fed to the even and odd polyphase branches of the filter processor. The output of each branch is multiplexed together to generate the output data stream at the interpolated rate. NOTE: The output of each polyphase branch is scaled by two to compensate for the attenuation of one half caused by interpolation.
FIGURE 9. TRANSVERSAL IMPLEMENTATION OF INTERPOLATE BY TWO HALFBAND FILTER
EVEN TAP FILTER ...,X2,X1,X0 ..,Y5,Y3,Y1
C0 C2 C4 C6 ODD TAP FILTER R E G
M U X
..,Y2,Y1,Y0
C1 C3 C5
..,Y4,Y2,Y0
Y0 = X0(C1)+X1(C3)+X2(C5) Y1 = X0(C0)+X1(C2)+X2(C4)+X3(C6) Y2 = X1(C1)+X2(C3)+X3(C5)
FIGURE 10. POLYPHASE IMPLEMENTATION OF INTERPOLATE BY TWO HALFBAND FILTER
AIN0-15 R E G R E G R E G 1
R E G
PIPELINE DELAY 2-35 GROUP DELAY 19
EVEN TAP FILTER
R E G 2 2 R E G AOUT0-15
Clocked at CLK/2
R E G
1
R E G
PIPELINE DELAY 19 GROUP DELAY 19
ODD TAP FILTER
R E G
M RFRR U NME E X DTGG
OEA
FIGURE 11A. DATA FLOW DIAGRAM FOR INTERPOLATE BY 2 FILTER MODE (INT/EXT = 1)
PIPELINE DELAY 2-35 GROUP DELAY 19 AIN0-15 R E G R E G R E G 1 PIPELINE DELAY 19 GROUP DELAY 19 1 R E G R E G ODD TAP FILTER 1 R E G RFRR NMEE DTGG OEB R E G EVEN TAP FILTER 1 R E G RFRR NMEE DTGG OEA
AOUT0-15
BOUT0-15
FIGURE 11B. DATA FLOW DIAGRAM FOR INTERPOLATE BY 2 FILTER MODE (INT/EXT = 0)
10
FN3365.9 April 18, 2007
HSP43216
If internal multiplexing is selected (INT/EXT = 1), the data stream input through AIN0-15 is fed to both the upper and lower processing legs as shown in Figure 11A. The output of each processing leg is then multiplexed together to produce the interpolated sample stream at twice the input sample rate. In this mode the device is clocked at the interpolated data rate to support the multiplexing of each processing leg's output into a single data stream. The upper and lower processing legs each run at the input data rate of CLK/2 as indicated by the " " marking the various registers and processing elements in Figure 11A. In this mode, data samples are clocked into the part on every other rising edge of CLK. The SYNC signal is used to specify which set of CLK cycles are used to register data at the part's input. Specifically, every other rising edge of CLK starting one CLK after the assertion of SYNC will be used to clock data into the part. With internal multiplexing the minimum pipeline delay through the upper processing leg is 15 CLK's and the pipeline delay through the lower processing leg is 48 CLK's, (2[19+3]+4). If external multiplexing is selected (INT/EXT = 0), the upper and lower processing legs are output through AOUT0-15 and BOUT0-15 for multiplexing into a single data stream off chip.This allows the processing legs to run at the maximum clock rate which coincides with an interpolated output data rate of 104 MSPS. NOTE: The samples output on BOUT0-15 precede those on AOUT0-15 in sample order. This requires a multiplexing scenario in which BOUT0-15 is selected before AOUT0-15. With external multiplexing, the minimum pipeline delay through the upper processing leg is 9 CLK's and the pipeline delay through the lower processing leg is 26 CLK's as shown in Figure 11B. In this mode SYNC has no effect on part operation. By examining the combination of down conversion, filtering and decimation, it is seen that the real outputs are only dependent on the sum-of-products for the even indexed samples and filter coefficients, and the imaginary outputs are only a function of the sum-of-products for the odd indexed samples and filter coefficients. This computational partitioning allows the quadrature filters required after down conversion to be realized using the same poly-phase processing elements used in the previous two modes. A functional block diagram of the polyphase implementation is shown in Figure 14. In this implementation, the input data stream is broken into even and odd sample streams and processed independently by the even and odd tap filters. By decomposing the sample stream into even and odd samples, the zero mix terms produced by the down convert LO drop out of the data streams, and the output of each of the filters represent the decimated data streams for both the real and imaginary outputs.
INPUT SIGNAL SPECTRUM
-fS/2
0
fS/2
fS
DOWN CONVERTED SIGNAL
-fS/2
0
fS/2
fS
FILTERED SIGNAL FILTER PASSBAND
Down Convert and Decimate Mode (MODE1-0 = 10)
In Down Convert and Decimate Mode a real input signal is spectrally shifted -fS/4 which centers the upper sideband at DC. This operation produces real and imaginary components which are each filtered and decimated by identical 67-tap halfband filters. For added flexibility, a positive fS/4 spectral shift may be selected which centers the lower sideband at DC. The direction of the spectral shift is selected via USB/LSB as described in the Quadrature Down Convert section. A spectral representation of the down convert and decimate operation is shown in Figure 12 (USB/LSB = 1). NOTE: Each of the complex terms output by the Filter Processor are scaled by two to compensate for the attenuation of one half introduced by the down conversion process. The Down Convert and Decimate mode is most easily understood by first considering the transversal implementation using a 7 tap filter as shown in Figure 13.
-fS/2 0 fS/2 fS
DECIMATED OUTPUT SIGNAL SPECTRUM
-f'S
0
f'S
2f'S
fS = INPUT SAMPLE RATE f'S = DECIMATED SAMPLE RATE, fS/2
FIGURE 12. DOWN CONVERT AND DECIMATE OPERATION
11
FN3365.9 April 18, 2007
HSP43216
HALFBAND FILTER ...X2,X1,X0 C0 C1 C2 C3 C4 C5 C6 1, 0,-1, 0... COS(n/2) HALFBAND FILTER ...,I2,I0 2 C0 C1 C2 C3 C4 C5 C6 0,-1,0,1... SIN(-n/2) REAL OUTPUTS R0 = X0(C0)+0(C1)-X2(C2)+0(C3)+X4(C4)+0(C5)-X6(C6) ...,R2,R0
2
R1 = 0(C0)-X2(C1)+0(C2)+X4(C3)+0(C4)-X6(C5)+0(C6)
R2 = -X2(C0)+0(C1)+X4(C2)+0(C3)-X6(C4)+0(C5)+X4(C6)
R3 = 0(C0)+X4(C1)+0(C2)-X6(C3)+0(C4)+X4(C5)+0(C6)
The HSP43216's implementation of Down Convert and Decimate mode is analogous to the polyphase solution shown in Figure 14. The part's data flow diagram for this mode is shown in Figure 15A and Figure 15B. As seen in the figures, the input sample data is broken into even and odd sample streams which feed the upper and lower processing legs as described in the Decimate By 2 Mode section. The data on each processing leg is then modulated with the nonzero quadrature components of the complex exponent (see Quadrature Down Convert Section). Following this operation, the upper leg becomes the processing chain for the real (In-phase) component of the quadrature down conversion and the lower leg processes the complex (Quadrature) component of the down conversion. The filter processing block implements the equivalent of a decimate by two Halfband filter on each of the quadrature legs. If internal multiplexing is specified (INT/EXT = 1), the upper and lower processing legs are fed with even and odd sample streams which are derived from data input through AIN0-15. The input sample stream may be synchronized with the zero degree phase term of the down converter LO by using the SYNC control input. For example, an input data sample will be fed into the real (upper) processing leg and mixed with the zero degree cosine term of the quadrature LO if it is input on the 4th CLK following the assertion of SYNC as shown in Figure 16. The pipeline delay through the real processing leg (upper leg) is 14 CLK's and the delay through the imaginary processing leg (lower leg) is 47 CLK's. The complex samples output through AOUT0-15 and BOUT0-15 are present for 2 CLK's since the quadrature streams have been decimated by two in the filter processor.
IMAGINARY OUTPUTS

I0 = 0(C0)-X1(C1)+0(C2)+X3(C3)+0(C4)-X5(C5)+0(C6) I1 = -X1(C0)+0(C1)+X3(C2)+0(C3)-X5(C4)+0(C5)+X7(C6) I2 = 0(C0)+X3(C1)+0(C2)-X5(C3)+0(C4)+X7(C5)+0(C6) I3 = X3(C0)+0(C1)-X5(C2)+0(C3)+X7(C4)+0(C5)-X9(C6)
Indicates samples discarded by decimation process
FIGURE 13. DOWN CONVERT AND DECIMATE FUNCTION USING TRANSVERSAL FILTERS
EVEN TAP FILTER ...,X4,X2,X0 ...,R1,R0 C0 C2 C4 C6 1,-1,1,-1,.. COS LO
ODD TAP FILTER R E G ...,I1,I0 C1 C3 C5
...,X5,X3,X1
-1,1,-1,1.. SIN LO
REAL OUTPUTS R0 = X0(C0)-X2(C2)+X4(C4)-X6(C6) R1 = -X2(C0)+X4(C2)-X6(C4)+X8(C6) R2 = X4(C0)-X6(C2)+X8(C4)-X10(C6)
IMAGINARY OUTPUTS I0 = -X1(C1)+X3(C3)-X5(C5) I1 = X3(C1)-X5(C3)+X7(C5) I2 = -X5(C1)+X7(C3)-X9(C5)
FIGURE 14. DOWN CONVERT AND DECIMATE FUNCTION USING POLYPHASE FILTERS
12
FN3365.9 April 18, 2007
HSP43216
PIPELINE DELAY 2-35 GROUP DELAY 19
EVEN TAP FILTER 2
AIN0-15 R E G R E G R E G
R E G 1,-1,1,-1,... -1,1,-1,1,...
R E G RFRR NMEE DTGG AOUT0-15 OEA
R E G
R E G
PIPELINE DELAY 19 GROUP DELAY 19
ODD TAP FILTER
2
R E G RFRR NME E DTGG BOUT0-15 OEB
Clocked at CLK/2
FIGURE 15A. DATA FLOW DIAGRAM FOR DOWN CONVERT AND DECIMATE MODE (INT/EXT = 1)
PIPELINE DELAY 2-35 GROUP DELAY 19 AIN0-15 R E G R E G R E G R E G 1,-1,1,-1,... -1,1,-1,1,... BIN0-15 R E G R E G R E G R E G EVEN TAP FILTER 2 2 R E G RFRR NMEE DTGG R E G RFRR NMEE DTGG AOUT0-15
PIPELINE DELAY 19 GROUP DELAY 19 ODD TAP FILTER
OEA BOUT0-15
OEB
FIGURE 15B. DATA FLOW DIAGRAM FOR DOWN CONVERT AND DECIMATE MODE (INT/EXT = 0)
0 CLK SYNC
1
2
3
the demultiplex function would route x0 and x2 to AIN015 and x1 and x3 to BIN0-15.
0 1 2
AIN0-15
0o
90o
180o
270o
CLK SYNC
THE SAMPLE DESIGNATED BY THE 0o AND 180o LABELS ARE MIXED WITH THE RESPECTIVE COSINE TERMS ON THE UPPER PROCESSING LEG, AND THE OTHER SAMPLES, THOSE LABELED BY 90o AND 270o, ARE MIXED WITH THE RESPECTIVE SINE TERMS ON THE LOWER LEG.
AIN0-15
0o
180o
0o
180o
FIGURE 16. DATA SYNCHRONIZATION TO 0o PHASE OF QUADRATURE LO
THE 0o AND 180o LABELS INDICATE THE PHASE ALIGNMENT OF THE SAMPLES INPUT THROUGH AIN0-15 WITH THE COSINE TERM OF THE QUADRATURE DOWN CONVERT LO.
If external multiplexing is selected (INT/EXT = 0), a demultiplex function is required off chip to break the input data stream into even and odd samples for input through AIN0-15 and BIN0-15. In this mode, the real and imaginary processing legs run at the input clock rate which allows the device to perform the down convert and decimate function on real signals sampled at up to twice the maximum speed grade of the device (104 MSPS). With external multiplexing, the minimum pipeline delay through the upper processing leg is 9 CLK's and the pipeline delay through the lower processing leg is 26 CLK's as shown in Figure 15B. To synchronize the even samples input through AIN0-15 with the zero degree cosine term of the quadrature LO, SYNC should be asserted on the same clock that the target sample is present at the input of the part as shown in Figure 17. NOTE: For proper operation, the samples demultiplexed to the AIN0-15 input must precede those input to the BIN0-15 input in sample order. For example, given a data sequence x0, x1, x2, and x3,
FIGURE 17. DATA SYNCHRONIZATION WITH PHASE OF DOWN CONVERT LO
Quadrature to Real Conversion Mode (MODE1-0 = 11) The Quadrature to Real Conversion mode is used to construct a real output from a quadrature input. To accomplish this, the Halfband Filter Processor interpolates the quadrature components of the complex input signal by a factor of two. Next, the Quadrature Up-Convert Processor spectrally shifts the signal by fS/4 and derives the real output as described in the fS/4 Quadrature Up-Convert Processor Section. The direction of the spectral shift is controlled via the USB/LSB input and is used to designate the frequency content of the complex input as either the upper or lower sideband of the resulting real output signal. A spectral representation of quadrature to real conversion is shown in Figure 18 for USB/LSB = 1. NOTE: The fS/4 Up-Convert Processor uses quadrature mix factors
13
FN3365.9 April 18, 2007
HSP43216
scaled by two to compensate for the attenuation introduced by the interpolation process.
INPUT SIGNAL SPECTRUM ..R1,R0 2 ..R1,0,R0,0 C0 C1 C2 C3 C4 C5 C6 ..,Y2,Y1,Y0 HALFBAND FILTER -fS 0 fS 2fS ..I1,I0 INTERPOLATED SIGNAL FILTER PASSBAND 2 ..I1,0,I0,0 C0 C1 C2 C3 C4 C5 C6 -1,0,1,0... SIN(-(n+1)/2) HALFBAND FILTER COS((n+1)/2) 0,1,0,-1...
+
-f'S/2
0
f'S/2
f'S
Y(0) = 0(0(C0)+R0(C1)+0(C2)+R1(C3)+0(C4)+R2(C5)+0(C6))+ -1(0(C0)+I0(C1)+0(C2)+I1(C3)+0(C4)+I2(C5)+0(C6)) Y(1) = 1(R0(C0)+0(C1)+R1(C2)+0(C3)+R2(C4)+0(C5)+R3(C6))+ 0(I0(C0)+0(C1)+I1(C2)+0(C3)+I2(C4)+0(C5)+I3(C6)) Y(2) = 0(0(C0)+R1(C1)+0(C2)+R2(C3)+0(C4)+R3(C5)+0(C6))+ 1(0(C0)+I1(C1)+0(C2)+I2(C3)+0(C4)+I3(C5)+0(C6))
UPCONVERTED SIGNAL
-f'S/2
0
f'S/2
f'S
Y(3) = -1(R1(C0)+0(C1)+R2(C2)+0(C3)+R3(C4)+0(C5)+R4(C6))+ 0(I1(C0)+0(C1)+I2(C2)+0(C3)+I3(C4)+0(C5)+I4(C6))
REAL OUTPUT
FIGURE 19. QUADRATURE TO REAL CONVERTER USING TRANSVERSAL FILTERS
-f'S/2 0 f'S/2 f'S EVEN TAP FILTER ..R1,R0
fS = INPUT SAMPLE RATE f'S = INTERPOLATED SAMPLE RATE, 2fS
FIGURE 18. QUADRATURE TO REAL CONVERSION
C0 C2 C4 C6 1,-1,1,-1,.. COS LO M U X ..,Y2,Y1,Y0
The Quadrature to Real Conversion mode is most easily understood by first considering an implementation using a 7 tap transversal filter as shown in Figure 19. By examining the combination of interpolation, filtering, and up conversion it is seen that a particular output is only dependent on the sum-of-products for the even indexed samples and coefficients or the sum-of-products for the odd indexed samples and coefficients. This computational partitioning allows the dual interpolation filters required in this mode to be realized using the same polyphase filter structure used in the other modes. A functional block diagram of the polyphase implementation for Quadrature to Real Conversion mode is shown in Figure 20. In this implementation, the real and imaginary components of a complex input stream drive the even and odd tap filters. The output of each filter is then modulated by the non-zero mix factors and multiplexed into a single real output stream.
ODD TAP FILTER R E G
..I1,I0
C1 C3 C5 -1,1,-1,1.. SIN LO
Y(0) = -1(I0(C1)+I1(C3))+I2(C5)) Y(1) = 1(R0(C0)+R1(C2)+R2(C4))+R3(C6)) Y(2) = 1(I1(C1)+I2(C3)+I3(C5)) Y(3) = -1(R1(C0)+R2(C2)+R3(C4)+R4(C6))
FIGURE 20. POLYPHASE IMPLEMENTATION OF QUADRATURE TO REAL CONVERTER
14
FN3365.9 April 18, 2007
HSP43216
PIPELINE DELAY 2-35 GROUP DELAY 19
EVEN TAP FILTER
AIN0-15 R E G R E G R E G 1
R E G
R E G 2,-2,2,-2,... R E G
BIN0-15 R E G R E G R E G
1
R E G
PIPELINE DELAY 19 GROUP DELAY 19
ODD TAP FILTER
-2,2,-2,2,... R E G
M RFRR U NMEE X DTGG
AOUT0-15 OEA
Clock at Input data rate, CLK/2
FIGURE 21A. DATA FLOW DIAGRAM FOR QUADRATURE TO REAL CONVERSION MODE (INT/EXT = 1)
PIPELINE DELAY 2-32 GROUP DELAY 19 AIN0-15 R E G R E G R E G 1 1 BIN0-15 R E G R E G R E G R E G PIPELINE DELAY 19 GROUP DELAY 19 ODD TAP FILTER R E G EVEN TAP FILTER R E G 2,-2,2,-2,... -2,2,-2,2,... R E G RFRR NMEE DTGG BOUT0-15 OEB RFRR NMEE DTGG AOUT0-15 OEA
FIGURE 21B. DATA FLOW DIAGRAM FOR QUADRATURE TO REAL CONVERSION MODE (INT/EXT = 0)
As in the other modes, the operation of the HSP43216 in Quadrature to real Conversion mode is analogous to that of the polyphase solution described above. The data flow diagrams for this particular mode are shown in Figures 21A and 21B. If Internal Multiplexing is specified (INT/EXT = 1), the real and imaginary components of the quadrature input are fed through AIN0-15 and BIN0-15 and processed on the upper and lower legs respectively (see Figure 21A). Each component of the complex input is interpolated, mixed with the non-zero sine and cosine terms of the quadrature LO, and multiplexed together into a real output sample stream through AOUT0-15. Prior to the output multiplexer, the upper and lower processing legs each run at the input data rate of CLK/2 as indicated by the " " marking the various registers and processing elements in Figure 21A. The complex input sample stream may be synchronized with the zero degree phase of the up converters quadrature LO by asserting the SYNC control input one cycle prior to the targeted data sample as shown in Figure 22. This ensures that the real sample input on the upper processing leg will be mixed with the zero degree cosine term. The minimum pipeline delay through the real processing leg (upper leg) is 15 CLK's and the delay through the imaginary processing leg (lower leg) is 48 CLK's.
0 CLK/2 SYNC
AIN0-15 BIN0-15
FIGURE 22. DATA SYNCHRONIZATION WITH PROCESSING LEGS (INT/EXT = 1)
If external multiplexing is selected (INT/EXT = 0), output from the upper and lower processing legs exit through AOUT0-15 and BOUT0-15 for multiplexing into a single data stream off chip (see Figure 21B).This allows the processing legs to run at the maximum CLK rate which coincides with an interpolated output data rate of up to 104 MSPS. NOTE: The output on BOUT0-15 precedes that on AOUT0-15 in sample order. This requires a multiplexing scenario which selects BOUT0-15 then AOUT0-15 on each CLK of the HSP43216. With external multiplexing, the minimum pipeline delay through the upper processing leg is 9 CLK's and the pipeline delay through the lower processing leg is 26 CLK's as shown in Figure 21B. The SYNC control input is used as described in the preceding paragraph.
15
FN3365.9 April 18, 2007
HSP43216
Absolute Maximum Ratings
Supply Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +7.0V Input, Output or I/O Voltage . . . . . . . . . . . . GND -0.5V to VCC +0.5V ESD Classification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Class 1
Thermal Information
Thermal Resistance (Typical, Note 1) JA (C/W) JC (C/W) PLCC Package. . . . . . . . . . . . . . . . . . . 23.0 N/A MQFP Package . . . . . . . . . . . . . . . . . . 35.0 N/A Maximum Junction Temperature PLCC and MQFP Packages . . . . . . . . . . . . . . . . . . . . . . . +150C Maximum Storage Temperature Range . . . . . . . . . .-65C to +150C Maximum Lead Temperature (Soldering 10s) . . . . . . . . . . . . +300C
Operating Conditions
Voltage Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . +4.75V to +5.25V Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . 0C to +70C
Die Characteristics
Gate Count . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35469 Gates
CAUTION: Stresses above those listed in "Absolute Maximum Ratings" may cause permanent damage to the device. This is a stress only rating and operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied.
NOTE: 1. JA is measured with the component mounted on an evaluation PC board in free air.
DC Electrical Specifications
PARAMETER Power Supply Current
VCC = 5.0V 5%, TA = 0 to +70C SYMBOL ICCOP TEST CONDITIONS VCC = Max, CLK Frequency 52MHz INT/EXT = `1', Notes 2, 4 VCC = Max, CLK Frequency 52MHz INT/EXT = `0', Notes 3, 4 MIN MAX 468 UNITS mA
-
572
mA A A A V V V V V V pF pF
Standby Power Supply Current Input Leakage Current Output Leakage Current Clock Input High Clock Input Low Logical One Input Voltage Logical Zero Input Voltage Logical One Output Voltage Logical Zero Output Voltage Input Capacitance Output Capacitance NOTES:
ICCSB II IO VIHC VILC VIH VIL VOH VOL CIN COUT
VCC = Max, Outputs Not Loaded VCC = Max, Input = 0V or VCC VCC = Max, Input = 0V or VCC VCC = Max VCC = Min VCC = Max VCC = Min IOH = -3mA, VCC = Min IOL = 5mA, VCC = Min CLK Frequency 1MHz, All measurements referenced to GND. TA = +25C, Note 5
-10 -10 3.0 2.0 2.6 -
500 10 10 0.8 0.8 0.4 12 12
2. Power supply current is proportional to frequency. Typical rating is 9mA/MHz when Internal Multiplexing is selected, INT/EXT = 1. 3. Power supply current is proportional to frequency. Typical rating is 11mA/MHz when External Multiplexing is selected, INT/EXT = 0. 4. Output load per test circuit and CL = 40pF. 5. Not tested, but characterized at initial design and at major process/design changes. 6. Maximum junction temperature must be considered when operating part at high clock frequencies.
16
FN3365.9 April 18, 2007
HSP43216
AC Electrical Specifications
(Note 7) 52MHz PARAMETER CLK Period CLK High CLK Low Setup Time AIN0-15, BIN0-15 to CLK Hold Time AIN0-15, BIN0-15 from CLK MODE0-1, RND0-2, INT/EXT, SYNC, USB/LSB Setup Time to CLK MODE0-1, RND0-2, INT/EXT, SYNC, USB/LSB Hold Time to CLK CLK to AOUT0-15, BOUT0-15 Delay Output Enable Time Output Disable Time Output Rise, Output Fall Times NOTES: 7. AC tests performed with CL = 40pF, IOL = 5mA, and IOH = -3mA. Input reference level for CLK is 2.0V, all other inputs 1.5V. Test VIH = 3.0V, VIHC = 4.0V, VIL = 0V. 8. Controlled via design or process parameters and not directly tested. Characterized upon initial design and after major process and/or changes. SYMBOL tCP tCH tCL tDS tDH tRS tRH tDO tOE tOD tr, tf Note 8 Note 8 NOTES MIN 19 7 7 7 0 7 0 MAX 9 9 9 5 UNITS ns ns ns ns ns ns ns ns ns ns ns
AC Test Load Circuit
DUT
S1
CL (NOTE)
SWITCH S1 OPEN FOR ICCSB AND ICCOP IOH 1.5V IOL
EQUIVALENT CIRCUIT
NOTE: Test head capacitance.
17
FN3365.9 April 18, 2007
HSP43216 Waveforms
tCP tCH CLK tCL
tDS AIN0-15, BIN-15
tDH
MODE0-1, RND0-2, INT/EXT, SYNC, USB/LSB
tRS
tRH
tDO AOUT0-15, BOUT0-15
tOD OE
tOE
FIGURE 23. TIMING RELATIVE TO CLK
tr
tf
2.0V 0.8V
FIGURE 24. OUTPUT RISE AND FALL TIMES
18
FN3365.9 April 18, 2007
HSP43216 Plastic Leaded Chip Carrier Packages (PLCC)
0.042 (1.07) 0.048 (1.22) PIN (1) IDENTIFIER C L 0.042 (1.07) 0.056 (1.42) 0.050 (1.27) TP
N84.1.15 (JEDEC MS-018AF ISSUE A)
0.004 (0.10) C
84 LEAD PLASTIC LEADED CHIP CARRIER PACKAGE INCHES SYMBOL A A1 MIN 0.165 0.090 1.185 1.150 0.541 1.185 1.150 0.541 84 MAX 0.180 0.120 1.195 1.158 0.569 1.195 1.158 0.569 MILLIMETERS MIN 4.20 2.29 30.10 29.21 13.75 30.10 29.21 13.75 84 MAX 4.57 3.04 30.35 29.41 14.45 30.35 29.41 14.45 NOTES 3 4, 5 3 4, 5 6 Rev. 2 11/97
0.025 (0.64) R 0.045 (1.14)
D2/E2 E1 E C L D2/E2 VIEW "A"
D D1 D2 E E1 E2 N
D1 D 0.020 (0.51) MAX 3 PLCS
A1 A
0.020 (0.51) MIN SEATING -C- PLANE
0.026 (0.66) 0.032 (0.81)
0.013 (0.33) 0.021 (0.53)
0.045 (1.14) MIN
0.025 (0.64) MIN VIEW "A" TYP.
NOTES: 1. Controlling dimension: INCH. Converted millimeter dimensions are not necessarily exact. 2. Dimensions and tolerancing per ANSI Y14.5M-1982. 3. Dimensions D1 and E1 do not include mold protrusions. Allowable mold protrusion is 0.010 inch (0.25mm) per side. Dimensions D1 and E1 include mold mismatch and are measured at the extreme material condition at the body parting line. 4. To be measured at seating plane -C- contact point. 5. Centerline to be determined where center leads exit plastic body. 6. "N" is the number of terminal positions.
19
FN3365.9 April 18, 2007
HSP43216 Metric Plastic Quad Flatpack Packages (MQFP)
D D1 -D-
Q100.14x20 (JEDEC MS-022GC-1 ISSUE B)
100 LEAD METRIC PLASTIC QUAD FLATPACK PACKAGE INCHES SYMBOL A A1 A2 b b1 D D1 E E1 L N e
SEATING A PLANE 0.076 0.003
MILLIMETERS MIN 0.25 2.57 0.22 0.22 23.08 19.88 17.10 13.90 0.73 100 0.65 BSC 30 20 MAX 3.40 2.87 0.38 0.33 23.32 20.12 17.30 14.10 1.03 NOTES 6 3 4, 5 3 4, 5 7 Rev. 1 4/99
MIN 0.010 0.101 0.009 0.009 0.908 0.782 0.673 0.547 0.029 100
MAX 0.134 0.113 0.015 0.013 0.918 0.792 0.681 0.555 0.040
-AE E1
-B-
e
PIN 1
0.026 BSC 30 20
-H-
ND NE NOTES:
0.40 0.016 MIN 0o MIN 0o-7o
12o-16o 0.20 M 0.008 A2 A1 C A-B S
-CDS b b1 0.13/0.17 0.005/0.007 BASE METAL WITH PLATING 0.13/0.23 0.005/0.009
1. Controlling dimension: MILLIMETER. Converted inch dimensions are not necessarily exact. 2. All dimensions and tolerances per ANSI Y14.5M-1982. 3. Dimensions D and E to be determined at seating plane -C- . 4. Dimensions D1 and E1 to be determined at datum plane -H- . 5. Dimensions D1 and E1 do not include mold protrusion. Allowable protrusion is 0.25mm (0.010 inch) per side. 6. Dimension b does not include dambar protrusion. Allowable dambar protrusion shall be 0.08mm (0.003 inch) total. 7. "N" is the number of terminal positions.
L
12o-16o
All Intersil U.S. products are manufactured, assembled and tested utilizing ISO9000 quality systems. Intersil Corporation's quality certifications can be viewed at www.intersil.com/design/quality
Intersil products are sold by description only. Intersil Corporation reserves the right to make changes in circuit design, software and/or specifications at any time without notice. Accordingly, the reader is cautioned to verify that data sheets are current before placing orders. Information furnished by Intersil is believed to be accurate and reliable. However, no responsibility is assumed by Intersil or its subsidiaries for its use; nor for any infringements of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of Intersil or its subsidiaries.
For information regarding Intersil Corporation and its products, see www.intersil.com 20
FN3365.9 April 18, 2007


▲Up To Search▲   

 
Price & Availability of HSP4321607

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X